Neck Pacing During AF Cryoablation - EMJ

This site is intended for healthcare professionals

Neck Pacing Offers Alternative During Atrial Fibrillation Cryoablation

Author:
Neck Pacing During AF Cryoablation - EMJ

Key Summary:

  • Researchers evaluated right neck phrenic nerve pacing during atrial fibrillation cryoablation.
  • Neck stimulation successfully paced the nerve in 92% of patients.
  • Findings support further evaluation of neck pacing as an alternative to conventional methods.

Atrial fibrillation (AF) cryoablation could be performed using phrenic nerve pacing from the right side of the neck.

Researchers found that neck stimulation successfully paced the phrenic nerve in 92% of patients, without permanent nerve injuries or other reported complications associated with the approach.

Evaluating an Alternative Pacing Technique

Researchers investigated whether stimulation from the right side of the neck could provide an alternative approach.

The study included 104 patients with non-valvular AF who underwent cryoablation and each patient received phrenic nerve pacing from both the neck and SVC.

Researchers compared pacing during ablation of the right inferior and right superior pulmonary veins, with the pacing location alternated between patients.

Neck Pacing Demonstrates Feasibility

Right neck pacing was successfully achieved in 96 of the 104 patients (92%). When the two pacing approaches were compared, successful pacing during ablation was recorded in 87% of neck pacing procedures and 93% of SVC pacing procedures. This difference was not statistically significant.

Neck pacing also resulted in significantly shorter procedure and fluoroscopy times. The mean procedure time was 2.1 minutes with neck pacing, compared with 3.4 minutes using SVC pacing. Fluoroscopy time was 0 minutes and 2.2 minutes, respectively.

Patient Selection Remains Important

Further analysis identified neck circumference-to-height ratio and compound motor action potential (CMAP) amplitude at the onset of neck stimulation as independent predictors of unsuccessful pacing. A neck circumference-to-height ratio above 0.252 and lower CMAP values were associated with greater difficulty achieving effective stimulation.

Researchers noted that neck pacing may be less suitable for patients with neck obesity, in whom stimulation may be more difficult. Patients who could not be paced successfully from the neck were able to undergo pacing from the SVC.

The study was limited by its relatively small sample size and patient population and patients with carotid artery complications were also excluded, meaning the safety of the technique in this group remains uncertain.

Researchers concluded that right neck phrenic nerve pacing may be a feasible and safe alternative during cryoablation of right-sided pulmonary veins in selected patients with AF, particularly those without neck obesity. Further studies are needed to establish its wider applicability.

Reference:

Sakai T et al. Efficacy and safety of right neck phrenic nerve pacing in patients undergoing cryoablation for atrial fibrillation. J Cardiol.2026;88(5):399-407.

Featured image: freshidea on Adobe Stock

Each article is made available under the terms of the Creative Commons Attribution-Non Commercial 4.0 License.

Rate this content's potential impact on patient outcomes

Average rating 0 / 5. Vote count: 0